The Anderic CHQ7096TKIT adds wireless remote control to standard AC ceiling fans without a remote system. It includes the RR7096T thermostatic remote and the FAN28R-T (UC7067FCRX) receiver.
Specifications
- Kit: Anderic CHQ7096TKIT
- Radio frequency (RF)
- Batteries: 4 AAA (not included)
Good to Know
- The receiver installs in the fan's ceiling canopy.
- Controls only the down lights on fans with up and down lights.
- Does not reverse the fan; your fan needs a reverse switch on the motor housing for that.
- Follow the installation instructions included with the kit; for wiring questions, use a licensed electrician.
Setup / Pairing
A new kit comes with the remote and receiver already set to matching patterns. Check that both patterns match before closing the fan.
Installing the receiver in the canopy
- WARNING: High voltage. Turn off power to the fan by removing the fuse or switching off the circuit breaker.
- Remove the fan canopy from the mounting bracket.
- Disconnect the existing wiring between the fan and the supply at the junction box. If you are replacing a receiver, disconnect all of its wires.
- Lay the black antenna wire on top of the receiver and put the receiver in the mounting bracket.
- Connect with the supplied wire nuts: green fan wire to bare supply wire; black receiver wire (AC IN L) to black supply wire; white receiver wire (AC IN N) to white supply wire; white receiver wire (TO MOTOR N) to white fan wire; black receiver wire (TO MOTOR L) to black fan wire; blue receiver wire (FOR LIGHT) to blue light wire.
- Push the wires into the junction box and reinstall the canopy.
Setting the codes
- Before reinstalling the fan housing or canopy, note the dip switch pattern on the FAN28R-T receiver (or set it to the pattern you want).
- On the remote, remove the battery cover and slide the 4 dip switches up or down. The factory setting is all switches up; we recommend using a different combination.
- Set the switches on the remote to EXACTLY match the switches on the FAN28R-T receiver. The remote and receiver will only work together when both patterns are the same.
- Replace the battery cover, restore power and test the fan and light.
What's in the Box
- 1 remote and 1 receiver
- Wall mount bracket
- Batteries not included
Compatible Models
- Also works with: Campbell 52 in LED Indoor Brushed Nickel, Campbell 52 In. LED Indoor Mediterranean Bronze, WINDWARD IV 52INCH CEILING FAN
Before ordering, check the model or part number printed on your old remote (usually on the back or inside the battery compartment) and compare it to this list.
FCC ID : CHQ7096T
Frequency (MHz) : 303.875